Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 184
Filtrar
1.
Phys Chem Chem Phys ; 24(10): 5813-5822, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35226003

RESUMO

Sulfuric acid is shown to form a core-shell particle on a micron-sized, optically-trapped spherical silica bead. The refractive indices of the silica and sulfuric acid, along with the shell thickness and bead radius were determined by reproducing Mie scattered optical white light as a function of wavelength in Mie spectroscopy. Micron-sized silica aerosols (silica beads were used as a proxy for atmospheric silica minerals) were levitated in a mist of sulfuric acid particles; continuous collection of Mie spectra throughout the collision of sulfuric acid aerosols with the optically trapped silica aerosol demonstrated that the resulting aerosol particle had a core-shell morphology. Contrastingly, the collision of aqueous sulfuric acid aerosols with optically trapped polystyrene aerosol resulted in a partially coated system. The light scattering from the optically levitated aerosols was successfully modelled to determine the diameter of the core aerosol (±0.003 µm), the shell thickness (±0.0003 µm) and the refractive index (±0.007). The experiment demonstrated that the presence of a thin film rapidly changed the light scattering of the original aerosol. When a 1.964 µm diameter silica aerosol was covered with a film of sulfuric acid 0.287 µm thick, the wavelength dependent Mie peak positions resembled sulfuric acid. Thus mineral aerosol advected into the stratosphere would likely be coated with sulfuric acid, with a core-shell morphology, and its light scattering properties would be effectively indistinguishable from a homogenous sulfuric acid aerosol if the film thickness was greater than a few 100 s of nm for UV-visible wavelengths.

2.
Sci Adv ; 6(44)2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33127674

RESUMO

Volcanic emissions are a critical pathway in Earth's carbon cycle. Here, we show that aerial measurements of volcanic gases using unoccupied aerial systems (UAS) transform our ability to measure and monitor plumes remotely and to constrain global volatile fluxes from volcanoes. Combining multi-scale measurements from ground-based remote sensing, long-range aerial sampling, and satellites, we present comprehensive gas fluxes-3760 ± [600, 310] tons day-1 CO2 and 5150 ± [730, 340] tons day-1 SO2-for a strong yet previously uncharacterized volcanic emitter: Manam, Papua New Guinea. The CO2/ST ratio of 1.07 ± 0.06 suggests a modest slab sediment contribution to the sub-arc mantle. We find that aerial strategies reduce uncertainties associated with ground-based remote sensing of SO2 flux and enable near-real-time measurements of plume chemistry and carbon isotope composition. Our data emphasize the need to account for time averaging of temporal variability in volcanic gas emissions in global flux estimates.

5.
Opt Express ; 23(7): 9329-38, 2015 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-25968763

RESUMO

We report the transfer printing of blue-emitting micron-scale light-emitting diodes (micro-LEDs) onto fused silica and diamond substrates without the use of intermediary adhesion layers. A consistent Van der Waals bond was achieved via liquid capillary action, despite curvature of the LED membranes following release from their native silicon growth substrates. The excellence of diamond as a heat-spreader allowed the printed membrane LEDs to achieve optical power output density of 10 W/cm(2) when operated at a current density of 254 A/cm(2). This high-current-density operation enabled optical data transmission from the LEDs at 400 Mbit/s.

7.
Klin Lab Diagn ; (5): 56-9, 2014 May.
Artigo em Russo | MEDLINE | ID: mdl-25338466

RESUMO

The provision of medical laboratory services is a key element in diagnostic and treatment. The care of analytical quality remains in focus of attention. The interest to pre-analytical quality increased. However, alongside with it quality of post-analytical stage and such its significant element as support of timely and effective application of laboratory results in interest of patient has great importance. The purpose of study was to consider approaches to development of this aspect of medical laboratory practice and to demonstrate the modes which proved their effectiveness.


Assuntos
Comunicação Interdisciplinar , Ciência de Laboratório Médico/organização & administração , Pessoal de Laboratório Médico , Ciência de Laboratório Médico/métodos , Médicos , Recursos Humanos
8.
J Phys Chem A ; 118(38): 8817-27, 2014 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-25188692

RESUMO

Silica (SiO2) is an important mineral present in atmospheric mineral dust particles, and the heterogeneous reaction of N2O5 on atmospheric aerosol is one of the major pathways to remove nitrogen oxides from the atmosphere. The heterogeneous reaction of N2O5 with SiO2 has only been investigated by two studies previously, and the reported uptake coefficients differ by a factor of >10. In this work two complementary laboratory techniques were used to study the heterogeneous reaction of SiO2 particles with N2O5 at room temperature and at different relative humidities (RHs). The uptake coefficients of N2O5, γ(N2O5), were determined to be (7.2 ± 0.6) × 10(-3) (1σ) at 7% RH and (5.3 ± 0.8) × 10(-3) (1σ) at 40% RH for SiO2 particles, using the aerosol flow tube technique. We show that γ(N2O5) determined in this work can be reconciled with the two previous studies by accounting for the difference in geometric and BET derived aerosol surface areas. To probe the particle phase chemistry, individual micrometer sized SiO2 particles were optically levitated and exposed to a continuous flow of N2O5 at different RHs, and the composition of levitated particles was monitored online using Raman spectroscopy. This study represents the first investigation into the heterogeneous reactions of levitated individual SiO2 particles as a surrogate for mineral dust. Relative humidity was found to play a critical role: while no significant change of particle composition was observed by Raman spectroscopy during exposure to N2O5 at RH of <2%, increasing the RH led to the formation of nitrate species on the particle surface which could be completely removed after decreasing the RH back to <2%. This can be explained by the partitioning of HNO3 between the gas and adsorbed phases. The atmospheric implications of this work are discussed.

9.
Phys Chem Chem Phys ; 16(23): 11426-34, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24803083

RESUMO

The heterogeneous interactions of gas molecules on solid particles are crucial in many areas of science, engineering and technology. Such interactions play a critical role in atmospheric chemistry and in heterogeneous catalysis, a key technology in the energy and chemical industries. Investigating heterogeneous interactions upon single levitated particles can provide significant insight into these important processes. Various methodologies exist for levitating micron sized particles including: optical, electrical and acoustic techniques. Prior to this study, the optical levitation of solid micron scale particles has proved difficult to achieve over timescales relevant to the above applications. In this work, a new vertically configured counter propagating dual beam optical trap was optimized to levitate a range of solid particles in air. Silica (SiO2), α-alumina (Al2O3), titania (TiO2) and polystyrene were stably trapped with a high trapping efficiency (Q = 0.42). The longest stable trapping experiment was conducted continuously for 24 hours, and there are no obvious constraints on trapping time beyond this period. Therefore, the methodology described in this paper should be of major benefit to various research communities. The strength of the new technique is demonstrated by the simultaneous levitation and spectroscopic interrogation of silica particles by Raman spectroscopy. In particular, the adsorption of water upon silica was investigated under controlled relative humidity environments. Furthermore, the collision and coagulation behaviour of silica particles with microdroplets of sulphuric acid was followed using both optical imaging and Raman spectroscopy.

10.
Ann Clin Biochem ; 51(Pt 3): 312-25, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24477115

RESUMO

To enable consistency of investigation and the establishment of best practice standards, consensus guidelines were formulated previously by the UK National Poisons Information Service and the Association for Clinical Biochemistry. These joint guidelines have now been updated to reflect current best practice. The types of laboratory investigation required for poisoned patients are categorized as either (a) essential common laboratory investigations or (b) specific toxicological assays, and also as either (i) common or (ii) specialist or infrequent. Tests in categories (a) and (bi) should be available 24 hours per day, with a maximum turnaround time of 2 h. For the specialist assays, i.e. category (bii), availability and turnaround times have been specified individually. The basis for selection of these times has been clinical utility. The adoption of these guidelines, along with the use of the National Poisons Information Service (0844 8920111) and its online poisons information resource TOXBASE(®) (www.toxbase.org) enable the poisoned patient to receive appropriate, 'best practice' investigations according to their clinical needs and will avoid unnecessary investigations.


Assuntos
Análise Química do Sangue/métodos , Intoxicação/sangue , Hospitais , Humanos , Intoxicação/diagnóstico , Relatório de Pesquisa , Reino Unido
11.
Opt Lett ; 37(22): 4597-9, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23164850

RESUMO

Fibers of Er:YAG have been grown using the laser-heated pedestal growth method. Fibers with Er concentrations ranging from 0.5 to 10 mol. % have been produced and excitation at 965 nm has been used to produce intense upconversion emission at green and red wavelengths. The dependence of ground state absorption and upconversion emission on dopant concentration has been studied and shown to exhibit lower levels of self-absorption than previously reported. At Er concentrations of 5 mol. % and above; however, the variation of upconversion emission intensity with pump power deviates from theoretical predictions, exhibiting saturation behavior consistent with concentration quenching.

12.
Opt Lett ; 36(12): 2182-4, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21685960

RESUMO

High-concentration Er:YAG single-crystal fibers have been grown using the laser-heated pedestal growth technique. Instability in the melt and concomitant opacity of fibers were observed at source concentrations higher than 15 mol.%. Spectroscopic examination shows that broadening of the linewidth of the 4I(13/2) → 4I(15/2) transition is strongly dependent on Er³âº concentration.

13.
Oncogene ; 29(2): 297-304, 2010 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-19784069

RESUMO

MDM2 is an E3 ligase that promotes ubiquitin-mediated destruction of p53. Cellular stresses such as DNA damage can lead to p53 activation due in part to MDM2 destabilization. Here, we show that the stability of MDM2 is regulated by an ubiquitin-like NEDD8 pathway and identify NEDP1 as a chemotherapy-induced isopeptidase that deneddylates MDM2, resulting in MDM2 destabilization concomitant with p53 activation. Concordantly, RNAi-mediated knockdown of endogenous NEDP1 blocked diminution of MDM2 levels and increased chemoresistance of tumor cells. These findings unveil the regulation of MDM2 stability through NEDP1 as a common molecular determinant governing chemotherapy-induced p53-dependent cell death.


Assuntos
Endopeptidases/metabolismo , Proteínas Proto-Oncogênicas c-mdm2/metabolismo , Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Camptotecina/farmacologia , Linhagem Celular , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Endopeptidases/genética , Células HeLa , Humanos , Immunoblotting , Proteína NEDD8 , Estabilidade Proteica/efeitos dos fármacos , Proteínas Proto-Oncogênicas c-mdm2/genética , Interferência de RNA , Transfecção , Proteína Supressora de Tumor p53/metabolismo , Ubiquitinas/genética , Ubiquitinas/metabolismo , Zinostatina/farmacologia
14.
Nanotechnology ; 20(27): 275207, 2009 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-19528679

RESUMO

We have studied the room-temperature non-radiative energy transfer processes in hybrid structures composed of (Ga, In)N/GaN single quantum wells and semiconducting polymer blend films placed in nanometre-scale proximity. The blends consist of three polyfluorene materials with concentrations adjusted so that they emit white light. Power-dependent photoluminescence (PL) measurements are used to investigate the process of energy transfer from the quantum wells to the different components of the polymer blend. We show that energy distribution among the hybrid structures involves competition between nanoscale range non-radiative energy transfer processes from the inorganic well to the polymer components and within the blend itself.

16.
Ultrason Sonochem ; 15(2): 101-9, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17368071

RESUMO

Tuned cylindrical radial mode ultrasonic horns offer advantages over ultrasonic probes in the design of flow-through devices for bacterial inactivation. This study presents a comparison of the effectiveness of a radial horn and probe in the inactivation of Escherichia coli K12. The radial horn is designed using finite element analysis and the predicted modal parameters are validated using experimental modal analysis. A validated finite element model of the probe is also presented. Visual studies of the cavitation fields produced by the radial horn and probe are carried out using luminol and also backlighting to demonstrate the advantages of radial horns in producing a more focused cavitation field with widely dispersed streamers. Microbiological studies show that, for the same power density, better inactivation of E. coli K12 is achieved using the radial horn and, also, the radial horn offers greater achievable power density resulting in further improvements in bacterial inactivation. The radial horn is shown to be more effective than the probe device and offers opportunities to design in-line flow-through devices for processing applications.


Assuntos
Escherichia coli K12/efeitos da radiação , Ultrassom , Contagem de Colônia Microbiana , Análise de Elementos Finitos , Concentração de Íons de Hidrogênio , Modelos Estatísticos
17.
J Appl Microbiol ; 102(3): 766-73, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17309626

RESUMO

AIMS: The performance of three scanning CO(2) laser inactivation systems was assessed and included: a gantry system, a rapidly rotating mirror and a low-power hybrid system combining an oscillating mirror and rotary motion of the sample. METHODS AND RESULTS: Escherichia coli and Staphylococcus aureus were the target organisms on stainless steel, nutrient agar or moist collagen film and the laser power was varied from 2 to 1060 W (two laser sources). In general, a threshold energy density was identified, above which no inactivation was observed because the scanning velocity was too high (10 cm s(-1) for stainless steel, 660 W). Reducing the velocity increased the inactivation process until complete inactivation was observed at 1.3 cm s(-1) (E. coli, approximately 10(6) CFU per sample) and 0.82 cm s(-1) (S. aureus, approximately 10(8) CFU per sample); consequently, S. aureus organisms showed a greater resistance to laser irradiation. For the nutrient agar and collagen samples, the averages of the width of clearing were measured as a function of the translation velocity and the rates of inactivation (I(R), cm(2) s(-1)) were found; an optimum velocity was observed that produced the maximum rate of inactivation. At a laser power of 1060 W, the maximum value of I(R) was 140 cm(2) s(-1) ( approximately 10(7) CFU cm(-2)) for S. aureus on collagen and slightly less on nutrient agar (114 cm(2) s(-1), estimated from a best-fit polynomial, r(2) = 0.98). CONCLUSIONS: A comparison of the low- and high-power lasers produced values of 0.09 cm(2) s(-1) W(-1) (i.e. I(R) per Watt delivered) for S. aureus on nutrient agar with the low-power laser at 13 W and on collagen 0.13 cm(2) s(-1) W(-1) for 1060 W. The rate of inactivation was found to be a function of the laser power, translation velocity and properties of the substrate media. The three laser inactivation systems successfully demonstrated the potential speed, efficiency and application of such systems. SIGNIFICANCE AND IMPACT OF THE STUDY: Laser scanning systems offer the potential for rapid and efficient inactivation of surfaces, eliminating the need for chemical treatment.


Assuntos
Dióxido de Carbono , Escherichia coli/fisiologia , Lasers , Staphylococcus aureus/fisiologia , Ágar , Colágeno , Contagem de Colônia Microbiana , Meios de Cultura , Escherichia coli/efeitos da radiação , Aço Inoxidável , Staphylococcus aureus/efeitos da radiação
19.
Phys Rev Lett ; 97(8): 085501, 2006 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-17026313

RESUMO

Monte Carlo simulations of anomalous ion channeling in near-lattice-matched AlInN/GaN bilayers allow an accurate determination of the strain state of AlInN by Rutherford backscattering or channeling. Although these strain estimates agree well with x-ray diffraction (XRD) results, XRD composition estimates are shown to have limited accuracy, due to a possible deviation from Vegard's law, which we quantify for this alloy. As the InN fraction increases from 13% to 19%, the strain in AlInN films changes from tensile to compressive with lattice matching predicted to occur at [InN] = 17.1%.

20.
J Clin Pathol ; 59(9): 893-902, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16714397

RESUMO

This fourth best practice review examines four series of common primary care questions in laboratory medicine are examined in this review: (1) safety monitoring for three common drugs; (2) use of prostate-specific antigen; (3) investigation of vaginal discharge; and (4) investigation of subfertility. The review is presented in question-answer format, referenced for each question series. The recommendations represent a precis of the guidance found using a standardised literature search of national and international guidance notes, consensus statements, health policy documents and evidence-based medicine reviews, supplemented by Medline Embase searches to identify relevant primary research documents. They are not standards but form a guide to be set in the clinical context. Most of them are consensus based rather than evidence based. They will be updated periodically to take account of new information.


Assuntos
Patologia Clínica/métodos , Atenção Primária à Saúde/métodos , Infecções por Chlamydia/diagnóstico , Monitoramento de Medicamentos/métodos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Infertilidade/diagnóstico , Masculino , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/diagnóstico , Descarga Vaginal/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...